Assessment Year 2012
Principal Product Ball Bearings
NAICS 332991: Ball and Roller Bearing Manufacturing
SIC 3562: Ball and Roller Bearings
Sales Range $10
M
to 50
M
# of Employees 66
Plant Area 90,200
ft2
Annual Production 5,793,748
lb
Production Hrs. Annual 8,568
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $218,488 7,093,800
kWh
Electricity Demand $80,276 13,723
kW-mo/yr
Electricity Fees $1,995 -
Natural Gas $53,346 6,614
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $11,357 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,361

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,431 $17,319 $3,173
103,014
kWh
$1,258
-
kW-mo/yr
-
02 2.7135: Install occupancy sensors $1,471 $2,422 $1,471
47,796
kWh
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,805 $2,292 $1,191
38,644
kWh
$614
-
kW-mo/yr
-
04 2.4221: Install compressor air intakes in coolest locations $1,361 $918 $1,082
35,068
kWh
$279
-
kW-mo/yr
-
05 2.2443: Re-use or recycle hot or cold process exhaust air $1,225 $979 $353
11,447
kWh
- $872
-
MMBtu
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,064 $3,948 $778
25,218
kWh
$286
-
kW-mo/yr
-
TOTAL RECOMMENDED $11,357 $27,878 $8,048
261,187
kWh
$2,437
-
kW-mo/yr
$872
-
MMBtu
TOTAL IMPLEMENTED $1,361 $918 $1,082
35,068
kWh
$279
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs