Assessment Year | 2010 |
---|---|
Principal Product | printed paper |
NAICS | 323120: Support Activities for Printing |
SIC | 2761: Manifold Business Forms |
Sales Range | $50 M to 100M |
# of Employees | 185 |
Plant Area |
150,000
ft2
|
Annual Production | 72,500,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $556,735 | 7,852,754 |
kWh
|
$0.071 |
Electricity Demand | $110,431 | 21,024 |
kW-mo/yr
|
$5.25 |
Natural Gas | $79,978 | 7,909 |
MMBtu
|
$10.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $59,333 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $49,939 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $5,064 | $560 |
$4,544
62,903
kWh
|
$520
-
kW-mo/yr
|
- | |
02 | 2.2437: Recover waste heat from equipment | $21,840 | $1,000 | - | - |
$21,840
-
MMBtu
|
|
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,986 | $50 |
$1,712
23,712
kWh
|
$274
-
kW-mo/yr
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,736 | $1,440 |
$10,118
140,144
kWh
|
$1,618
-
kW-mo/yr
|
- | |
05 | 2.7314: Reduce ventilation air | $1,274 | $2,000 |
$1,274
17,644
kWh
|
- | - | |
06 | 2.2113: Repair or replace steam traps | $2,798 | $800 | - | - |
$2,798
-
MMBtu
|
|
07 | 2.1243: Use heat from boiler blowdown to preheat boiler feed water | $371 | $1,000 | - | - |
$371
-
MMBtu
|
|
08 | 2.2437: Recover waste heat from equipment | $5,763 | $2,360 | - | - |
$5,763
-
MMBtu
|
|
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,501 | $6,360 |
$7,330
101,525
kWh
|
$1,171
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $59,333 | $15,570 |
$24,978
345,928
kWh
|
$3,583
-
kW-mo/yr
|
$30,772
-
MMBtu
|
||
TOTAL IMPLEMENTED | $49,939 | $10,160 |
$21,992
304,572
kWh
|
$3,309
-
kW-mo/yr
|
$24,638
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs