Assessment Year | 2021 |
---|---|
Principal Product | Encapsulated Shelves and Smooth Cooktops |
NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $50 M to 100M |
# of Employees | 238 |
Plant Area |
327,215
ft2
|
Annual Production | 7,586,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $1,031,756 | 27,635,900 |
kWh
|
$0.037 | |
Electricity Demand | $1,022,504 | 48,832 |
kW-mo/yr
|
$20.94 | |
Natural Gas | $48,902 | 9,174 |
MMBtu
|
$5.33 | |
Waste Disposal Costs | |||||
Water Usage | $61,441 | 7,122 |
Tgal
|
$8.63 | |
TOTAL YEARLY COSTS | $2,164,603 | ||||
RECOMMENDED SAVINGS* | $25,504 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $17,035 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $1,556 | - |
$495
13,373
kWh
|
- |
$1,061
-
MMBtu
|
|
02 | 2.6211: Conserve energy by efficient use of vending machines | $2,096 | - |
$1,181
31,914
kWh
|
$915
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,747 | $85 |
$1,747
47,212
kWh
|
- | - | |
04 | 2.2612: Use cooling tower water instead of refrigeration | $8,469 | $3,263 |
$8,469
228,888
kWh
|
- | - | |
05 | 2.7135: Install occupancy sensors | $194 | $195 |
$194
5,249
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,442 | $22,030 |
$5,516
149,090
kWh
|
$5,926
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $25,504 | $25,573 |
$17,602
475,726
kWh
|
$6,841
-
kW-mo/yr
|
$1,061
-
MMBtu
|
||
TOTAL IMPLEMENTED | $17,035 | $22,310 |
$9,133
246,838
kWh
|
$6,841
-
kW-mo/yr
|
$1,061
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs