Assessment Year | 2009 |
---|---|
Principal Product | Trailers |
NAICS | 336212: Truck Trailer Manufacturing |
SIC | 3715: Truck Trailers |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
105,000
ft2
|
Annual Production | 663
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | South Dakota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $120,494 | 2,234,770 |
kWh
|
$0.054 |
Electricity Demand | $78,615 | 6,415 |
kW-mo/yr
|
$12.25 |
Natural Gas | $179,888 | 18,885 |
MMBtu
|
$9.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $47,903 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,949 | $19,383 |
$4,317
79,664
kWh
|
$5,632
-
kW-mo/yr
|
- | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $962 | $81 |
$417
7,706
kWh
|
$545
-
kW-mo/yr
|
- | - | |
03 | 2.7135: Install occupancy sensors | $1,603 | $4,551 |
$1,603
29,633
kWh
|
- | - | - | |
04 | 2.2437: Recover waste heat from equipment | $5,460 | $100 | - | - |
$5,460
-
MMBtu
|
- | |
05 | 2.4221: Install compressor air intakes in coolest locations | $3,180 | $560 |
$195
3,600
kWh
|
$2,985
-
kW-mo/yr
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,637 | $506 |
$2,978
54,981
kWh
|
$3,659
-
kW-mo/yr
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,414 | $25 |
$635
11,713
kWh
|
$779
-
kW-mo/yr
|
- | - | |
08 | 2.7314: Reduce ventilation air | $18,248 | $20,000 | - | - |
$18,248
-
MMBtu
|
- | |
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $450 | $134 | - | - | - |
$450
-
MMBtu
|
|
TOTAL RECOMMENDED | $47,903 | $45,340 |
$10,145
187,297
kWh
|
$13,600
-
kW-mo/yr
|
$23,708
-
MMBtu
|
$450
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs