Assessment Year | 2008 |
---|---|
Principal Product | Monolithic, insulated and fabricated glass |
NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
105,000
ft2
|
Annual Production | 10,000
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $334,485 | 6,622,007 |
kWh
|
$0.051 |
Electricity Demand | $109,226 | 21,900 |
kW-mo/yr
|
$4.99 |
Natural Gas | $7,610 | 621 |
MMBtu
|
$12.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $46,591 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,700 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $9,332 | $252 |
$7,862
155,302
kWh
|
$1,470
-
kW-mo/yr
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,663 | $45 |
$6,441
127,296
kWh
|
$1,222
-
kW-mo/yr
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $978 | $240 |
$821
16,223
kWh
|
$157
-
kW-mo/yr
|
|
04 | 2.2514: Cover open tanks | $881 | $225 |
$881
17,410
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $22,079 | $36,423 |
$18,559
366,789
kWh
|
$3,520
-
kW-mo/yr
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,172 | $1,917 |
$908
17,924
kWh
|
$264
-
kW-mo/yr
|
|
07 | 2.7135: Install occupancy sensors | $552 | $1,309 |
$552
10,875
kWh
|
- | |
08 | 2.4133: Use most efficient type of electric motors | $2,096 | $317 |
$1,762
34,818
kWh
|
$334
-
kW-mo/yr
|
|
09 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,838 | $15 |
$1,838
36,317
kWh
|
- | |
TOTAL RECOMMENDED | $46,591 | $40,743 |
$39,624
782,954
kWh
|
$6,967
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $12,700 | $1,816 |
$11,073
218,717
kWh
|
$1,627
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs