Assessment Year | 2004 |
---|---|
Principal Product | grain storage bins |
NAICS | 333241: Food Product Machinery Manufacturing |
SIC | 3556: Food Products Machinery |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
400,000
ft2
|
Annual Production | 2,500
pieces
|
Production Hrs. Annual | 3,876
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $121,249 | 2,797,520 |
kWh
|
$0.043 |
Electricity Demand | $41,161 | 8,436 |
kW-mo/yr
|
$4.88 |
Electricity Fees | $28,774 | - |
|
- |
Natural Gas | $178,510 | 26,919 |
MMBtu
|
$6.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $48,080 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,525 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,115 | $14 |
$659
20,543
kWh
|
$456
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,623 | $920 |
$3,317
103,323
kWh
|
$2,306
-
kW-mo/yr
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $3,243 | $1,090 |
$1,941
60,467
kWh
|
$1,302
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,608 | $2,591 |
$951
29,620
kWh
|
$657
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $1,911 | $1,820 |
$1,911
59,521
kWh
|
- | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $929 | $457 |
$473
14,729
kWh
|
$456
-
kW-mo/yr
|
- | |
07 | 2.6218: Turn off equipment when not in use | $3,967 | $148 |
$2,231
69,500
kWh
|
$1,736
-
kW-mo/yr
|
- | |
08 | 2.4322: Use or replace with energy efficient substitutes | $29,440 | $50,000 | - | - |
$29,440
-
MMBtu
|
|
09 | 2.7124: Make a practice of turning off lights when not needed | $244 | - |
$107
3,328
kWh
|
$138
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $48,080 | $57,040 |
$11,589
361,031
kWh
|
$7,051
-
kW-mo/yr
|
$29,440
-
MMBtu
|
||
TOTAL IMPLEMENTED | $17,525 | $7,026 |
$10,930
340,488
kWh
|
$6,595
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs