| Assessment Year | 2004 |
|---|---|
| Principal Product | Printing |
| NAICS | 323111: Commercial Printing (except Screen and Books) |
| SIC | 2752: Commercial Printing, Lithographic |
| Sales Range | $10 M to 50M |
| # of Employees | 65 |
| Plant Area |
50,000
ft2
|
| Annual Production | 17,000,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $107,468 | 3,125,000 |
kWh
|
$0.034 |
| Electricity Demand | $56,983 | 9,264 |
kW-mo/yr
|
$6.15 |
| Natural Gas | $93,406 | 14,301 |
MMBtu
|
$6.53 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $80,453 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $80,453 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $457 | $189 |
$217
11,980
kWh
|
$320
-
kW-mo/yr
|
- | $(-80.0) | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,036 | $20 |
$619
23,088
kWh
|
$417
-
kW-mo/yr
|
- | - | |
| 03 | 2.4226: Use / purchase optimum sized compressor | $895 | $2,750 |
$535
19,968
kWh
|
$360
-
kW-mo/yr
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,854 | $5,572 |
$1,454
54,316
kWh
|
$1,400
-
kW-mo/yr
|
- | - | |
| 05 | 2.4133: Use most efficient type of electric motors | $462 | - |
$272
10,151
kWh
|
$190
-
kW-mo/yr
|
- | - | |
| 06 | 2.2414: Use waste heat from hot flue gases to preheat | $74,749 | $162,500 | - | - |
$74,749
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $80,453 | $171,031 |
$3,097
119,503
kWh
|
$2,687
-
kW-mo/yr
|
$74,749
-
MMBtu
|
$(-80.0) | ||
| TOTAL IMPLEMENTED | $80,453 | $171,031 |
$3,097
119,503
kWh
|
$2,687
-
kW-mo/yr
|
$74,749
-
MMBtu
|
$(-80.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs