Assessment Year | 2002 |
---|---|
Principal Product | kosher and non-kosher meat products |
NAICS |
n/a
|
SIC | 2011: Meat Packing Plants |
Sales Range | $100 M to 500M |
# of Employees | 500 |
Plant Area |
102,000
ft2
|
Annual Production | 68,000,000
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $351,057 | 12,072,200 |
kWh
|
$0.029 |
Electricity Demand | $174,749 | 24,588 |
kW-mo/yr
|
$7.11 |
Natural Gas | $196,849 | 37,716 |
MMBtu
|
$5.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,419 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,950 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,638 | $324 |
$1,898
64,994
kWh
|
$740
-
kW-mo/yr
|
- | |
02 | 2.4221: Install compressor air intakes in coolest locations | $2,215 | $184 |
$1,623
55,637
kWh
|
$592
-
kW-mo/yr
|
- | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $517 | $15 |
$372
12,730
kWh
|
$145
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,039 | $10,736 |
$3,502
119,919
kWh
|
$1,537
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,826 | - |
$1,998
68,411
kWh
|
$828
-
kW-mo/yr
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $11,721 | - |
$8,727
298,885
kWh
|
$2,994
-
kW-mo/yr
|
- | |
07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,521 | $1,000 | - | - |
$4,521
-
MMBtu
|
|
08 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $10,351 | $18,000 | - | - |
$10,351
-
MMBtu
|
|
09 | 2.2136: Install / repair insulation on steam lines | $1,701 | $592 | - | - |
$1,701
-
MMBtu
|
|
10 | 2.2135: Repair and eliminate steam leaks | $1,890 | $200 | - | - |
$1,890
-
MMBtu
|
|
TOTAL RECOMMENDED | $43,419 | $31,051 |
$18,120
620,576
kWh
|
$6,836
-
kW-mo/yr
|
$18,463
-
MMBtu
|
||
TOTAL IMPLEMENTED | $17,950 | $1,116 |
$10,625
363,879
kWh
|
$3,734
-
kW-mo/yr
|
$3,591
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |