Assessment Year | 2002 |
---|---|
Principal Product | Wood cabinets |
NAICS |
n/a
|
SIC | 2434: Wood Kitchen Cabinets |
Sales Range | $50 M to 100M |
# of Employees | 80 |
Plant Area |
100,000
ft2
|
Annual Production | 416,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $149,267 | 3,591,000 |
kWh
|
$0.042 |
Natural Gas | $5,326 | 548 |
MMBtu
|
$9.72 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,827 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,296 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,588 | $316 |
$1,588
38,271
kWh
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $1,790 | $616 |
$1,790
43,141
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,088 | $381 |
$1,088
26,208
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $762 | $3,567 |
$762
18,357
kWh
|
|
05 | 2.7135: Install occupancy sensors | $834 | $1,264 |
$834
20,087
kWh
|
|
06 | 2.4133: Use most efficient type of electric motors | $3,935 | $279 |
$3,935
94,818
kWh
|
|
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,830 | $960 |
$1,830
44,096
kWh
|
|
TOTAL RECOMMENDED | $11,827 | $7,383 |
$11,827
284,978
kWh
|
||
TOTAL IMPLEMENTED | $6,296 | $2,273 |
$6,296
151,716
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs