Assessment Year 2002
Principal Product pressure formed plastic parts
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 104
Plant Area 85,300
ft2
Annual Production 85,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $121,440 3,504,400
kWh
Electricity Demand $49,896 10,584
kW-mo/yr
Natural Gas $4,499 560
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $195,960 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $6,909

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings Personnel Changes Savings Ancillary Material Cost Savings Primary Product Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,761 $311 $1,400
40,572
kWh
$361
-
kW-mo/yr
- - - -
02 2.4231: Reduce the pressure of compressed air to the minimum required $703 $18 $560
16,224
kWh
$143
-
kW-mo/yr
- - - -
03 2.4221: Install compressor air intakes in coolest locations $665 $288 $528
15,302
kWh
$137
-
kW-mo/yr
- - - -
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,428 $7,280 $1,751
50,752
kWh
$677
-
kW-mo/yr
- - - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $791 - $629
18,221
kWh
$162
-
kW-mo/yr
- - - -
06 2.7124: Make a practice of turning off lights when not needed $2,183 $4,500 $2,183
73,991
kWh
- - - - -
07 2.4133: Use most efficient type of electric motors $730 - $580
16,799
kWh
$150
-
kW-mo/yr
- - - -
08 3.7198: Reduce / eliminate use of disposable product $779 $2,494 - - $34
-
gal
$711 $34 -
09 4.451: Add additional production shift $185,920 $30,000 - - - - - $185,920
TOTAL RECOMMENDED $195,960 $44,891 $7,631
231,861
kWh
$1,630
-
kW-mo/yr
$34
-
gal
$711 $34 $185,920
TOTAL IMPLEMENTED $6,909 $7,593 $5,320
164,885
kWh
$810
-
kW-mo/yr
$34
-
gal
$711 $34 -