Assessment Year | 2001 |
---|---|
Principal Product | corrugated medium |
NAICS |
n/a
|
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
130,680
ft2
|
Annual Production | 80,800
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,260,280 | 53,185,680 |
kWh
|
$0.024 |
Electricity Demand | $12 | 45,096 |
kW-mo/yr
|
$0.000 |
Natural Gas | $3,975,002 | 1,008,900 |
MMBtu
|
$3.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $134,220 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $107,653 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $82,252 | - |
$48,703
1,963,840
kWh
|
$33,549
-
kW-mo/yr
|
- | - | |
02 | 2.1213: Direct warmest air to combustion intake | $25,087 | $2,000 | - | - |
$25,087
-
MMBtu
|
- | |
03 | 2.2113: Repair or replace steam traps | $6,681 | $1,205 | - | - |
$6,681
-
MMBtu
|
- | |
04 | 2.2135: Repair and eliminate steam leaks | $2,752 | $600 | - | - |
$2,752
-
MMBtu
|
- | |
05 | 2.4221: Install compressor air intakes in coolest locations | $6,596 | $414 |
$3,895
157,069
kWh
|
$2,701
-
kW-mo/yr
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,550 | $190 |
$2,102
84,739
kWh
|
$1,448
-
kW-mo/yr
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,769 | - |
$2,232
89,980
kWh
|
$1,537
-
kW-mo/yr
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,761 | $2,230 |
$821
33,104
kWh
|
$940
-
kW-mo/yr
|
- | - | |
09 | 2.6218: Turn off equipment when not in use | $292 | $900 |
$292
11,763
kWh
|
- | - | - | |
10 | 3.4115: Recover and reuse cooling water | $1,480 | $2,188 |
$(-93.0)
(-3,744)
kWh
|
$(-90.0)
-
kW-mo/yr
|
- |
$1,663
-
Tgal
|
|
TOTAL RECOMMENDED | $134,220 | $9,727 |
$57,952
2,336,751
kWh
|
$40,085
-
kW-mo/yr
|
$34,520
-
MMBtu
|
$1,663
-
Tgal
|
||
TOTAL IMPLEMENTED | $107,653 | $5,539 |
$58,045
2,340,495
kWh
|
$40,175
-
kW-mo/yr
|
$9,433
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs