Assessment Year | 2002 |
---|---|
Principal Product | Plastic containers |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 98 |
Plant Area |
75,800
ft2
|
Annual Production | 12,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $294,058 | 10,828,608 |
kWh
|
$0.027 |
Electricity Demand | $240,168 | 19,728 |
kW-mo/yr
|
$12.17 |
Natural Gas | $32,819 | 3,499 |
MMBtu
|
$9.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,118 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,947 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,924 | $537 |
$1,229
45,013
kWh
|
$695
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,147 | $2,412 |
$622
22,794
kWh
|
$525
-
kW-mo/yr
|
|
03 | 2.7135: Install occupancy sensors | $346 | $532 |
$346
12,677
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,726 | - |
$1,741
63,773
kWh
|
$985
-
kW-mo/yr
|
|
05 | 2.4133: Use most efficient type of electric motors | $6,150 | - |
$3,601
131,914
kWh
|
$2,549
-
kW-mo/yr
|
|
06 | 2.2691: Shut off cooling if cold outside air will cool process | $14,825 | $28,000 |
$10,081
369,250
kWh
|
$4,744
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $27,118 | $31,481 |
$17,620
645,421
kWh
|
$9,498
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $11,947 | $2,949 |
$7,193
263,494
kWh
|
$4,754
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs