Assessment Year | 2012 |
---|---|
Principal Product | Grey and Ductile Iron Castings |
NAICS | 331511: Iron Foundries |
SIC | 3462: Iron and Steel Forgings |
Sales Range | $5 M to 10M |
# of Employees | 25 |
Plant Area |
30,000
ft2
|
Annual Production | 3,000
ton
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $98,938 | 2,036,400 |
kWh
|
$0.049 |
Electricity Demand | $122,345 | 13,378 |
kW-mo/yr
|
$9.15 |
Electricity Fees | $28,903 | - |
|
- |
Natural Gas | $22,899 | 3,246 |
MMBtu
|
$7.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,685 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,165 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $435 | $200 |
$326
6,517
kWh
|
$109
-
kW-mo/yr
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $362 | $30 |
$271
5,422
kWh
|
$91
-
kW-mo/yr
|
- | - | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $488 | - | - |
$488
-
kW-mo/yr
|
- | - | |
04 | 2.6218: Turn off equipment when not in use | $2,696 | - |
$2,696
53,918
kWh
|
- | - | - | |
05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $27,100 | $78,000 | - | - | - |
$27,100
-
lb
|
|
06 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $236 | $79 | - | - |
$236
-
MMBtu
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $141 | $1,000 |
$120
2,383
kWh
|
$22
-
kW-mo/yr
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,227 | $1,535 |
$2,421
48,410
kWh
|
$806
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $34,685 | $80,844 |
$5,834
116,650
kWh
|
$1,515
-
kW-mo/yr
|
$236
-
MMBtu
|
$27,100
-
lb
|
||
TOTAL IMPLEMENTED | $4,165 | $2,765 |
$3,138
62,732
kWh
|
$1,027
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs