Assessment Year | 2001 |
---|---|
Principal Product | corrugated paperboard |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
180,000
ft2
|
Annual Production | 750,000
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $161,009 | 4,689,210 |
kWh
|
$0.034 |
Electricity Demand | $35,319 | 10,320 |
kW-mo/yr
|
$3.42 |
Natural Gas | $219,487 | 53,319 |
MMBtu
|
$4.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $85,756 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,593 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7313: Recycle air for heating, ventilation and air conditioning | $25,513 | $8,420 | - | - |
$25,513
-
MMBtu
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,710 | $356 |
$5,159
221,396
kWh
|
$3,551
-
kW-mo/yr
|
- | - | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,186 | $209 |
$706
30,318
kWh
|
$480
-
kW-mo/yr
|
- | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $612 | $60 |
$422
18,096
kWh
|
$190
-
kW-mo/yr
|
- | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,418 | $8,938 |
$1,707
73,268
kWh
|
$1,711
-
kW-mo/yr
|
- | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,142 | $1,126 |
$1,861
79,872
kWh
|
$1,281
-
kW-mo/yr
|
- | - | - | |
07 | 2.7135: Install occupancy sensors | $1,313 | $1,862 |
$1,313
56,361
kWh
|
- | - | - | - | |
08 | 2.7111: Reduce illumination to minimum necessary levels | $337 | $740 |
$337
14,480
kWh
|
- | - | - | - | |
09 | 2.4133: Use most efficient type of electric motors | $1,544 | $445 |
$914
39,213
kWh
|
$630
-
kW-mo/yr
|
- | - | - | |
10 | 2.1213: Direct warmest air to combustion intake | $1,127 | $254 | - | - |
$1,127
-
MMBtu
|
- | - | |
11 | 3.4151: Minimize water usage | $1,414 | $35 | - | - | - | - |
$1,414
-
Tgal
|
|
12 | 4.322: Eliminate old stock and modify inventory control | $37,440 | $30,000 | n/a | - | - | - | $37,440 | - |
TOTAL RECOMMENDED | $85,756 | $52,445 |
$12,419
533,004
kWh
|
$7,843
-
kW-mo/yr
|
$26,640
-
MMBtu
|
$37,440 |
$1,414
-
Tgal
|
||
TOTAL IMPLEMENTED | $13,593 | $2,758 |
$7,808
335,066
kWh
|
$4,371
-
kW-mo/yr
|
- | - |
$1,414
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs