Assessment Year 2000
Principal Product metal cans and caps
NAICS
n/a
SIC 3411: Metal Cans
Sales Range $10
M
to 50
M
# of Employees 75
Plant Area 326,000
ft2
Annual Production 80,000,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Nebraska

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $135,896 5,640,094
kWh
Electricity Demand $115,717 14,076
kW-mo/yr
Natural Gas $152,325 62,742
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $661,902 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,077

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Administrative Changes Savings
01 2.4221: Install compressor air intakes in coolest locations $1,706 $127 $1,029
42,204
kWh
$677
-
kW-mo/yr
- -
02 2.4231: Reduce the pressure of compressed air to the minimum required $1,482 $25 $895
36,928
kWh
$587
-
kW-mo/yr
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $854 $38 $516
21,102
kWh
$338
-
kW-mo/yr
- -
04 2.4133: Use most efficient type of electric motors $1,223 - $737
30,481
kWh
$486
-
kW-mo/yr
- -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,737 $5,177 $1,653
67,995
kWh
$1,084
-
kW-mo/yr
- -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $1,039 $2,715 $610
25,205
kWh
$429
-
kW-mo/yr
- -
07 2.7135: Install occupancy sensors $609 $665 $609
25,205
kWh
- - -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $652 - $393
16,120
kWh
$259
-
kW-mo/yr
- -
09 4.521: Clear and rent existing space $465,000 $350,000 - - - $465,000
10 4.441: Install automatic packing equipment $186,600 $90,000 - - $186,600 -
TOTAL RECOMMENDED $661,902 $448,747 $6,442
265,240
kWh
$3,860
-
kW-mo/yr
$186,600 $465,000
TOTAL IMPLEMENTED $2,077 $38 $1,253
51,583
kWh
$824
-
kW-mo/yr
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Administrative Changes Savings