Assessment Year | 1997 |
---|---|
Principal Product | lithographic printing |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 135 |
Plant Area |
115,000
ft2
|
Annual Production | 15,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $58,949 | 2,406,800 |
kWh
|
$0.024 |
Electricity Demand | $211,507 | 19,584 |
kW-mo/yr
|
$10.80 |
Natural Gas | $29,550 | 7,856 |
MMBtu
|
$3.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $54,287 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,170 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.2176: Increase use of automation | $27,121 | $32,200 |
$(-85.0)
(-3,517)
kWh
|
$(-194.0)
-
kW-mo/yr
|
- | - | $27,400 | - | - | |
02 | 2.7229: Air condition only space necessary | $8,478 | $11,500 |
$2,646
108,148
kWh
|
$5,832
-
kW-mo/yr
|
- | - | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $1,431 | $920 |
$873
35,756
kWh
|
$558
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 3.5313: Increase amount of waste recovered for resale | $5,570 | $700 | - | - | - |
$2,760
-
lb
|
- | - | $2,810 | |
05 | 2.2443: Re-use or recycle hot or cold process exhaust air | $4,841 | $8,840 | - | - |
$4,841
-
MMBtu
|
- | - | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,123 | $2,592 |
$1,931
78,839
kWh
|
$1,192
-
kW-mo/yr
|
- | - | - | - | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,477 | $25 |
$920
37,515
kWh
|
$557
-
kW-mo/yr
|
- | - | - | - | - | |
08 | 2.4221: Install compressor air intakes in coolest locations | $899 | $330 |
$562
22,860
kWh
|
$337
-
kW-mo/yr
|
- | - | - | - | - | |
09 | 3.1191: Change procedures / equipment / operating conditions | $111 | $30 | - | - | - |
$111
-
lb
|
- | - | - | |
10 | 2.8121: Apply for tax-free status for energy purchases | $1,236 | $250 | - | - | - | - | - | $1,236 | - | |
TOTAL RECOMMENDED | $54,287 | $57,387 |
$6,847
279,601
kWh
|
$8,282
-
kW-mo/yr
|
$4,841
-
MMBtu
|
$2,871
-
lb
|
$27,400 | $1,236 | $2,810 | ||
TOTAL IMPLEMENTED | $10,170 | $3,317 |
$2,851
116,354
kWh
|
$1,749
-
kW-mo/yr
|
- |
$2,760
-
lb
|
- | - | $2,810 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs