| Assessment Year | 1997 |
|---|---|
| Principal Product | beef products |
| NAICS |
n/a
|
| SIC | 2011: Meat Packing Plants |
| Sales Range | $100 M to 500M |
| # of Employees | 401 |
| Plant Area |
125,000
ft2
|
| Annual Production | 539,000
pieces
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $465,715 | 19,248,242 |
kWh
|
$0.024 |
| Electricity Demand | $357,322 | 42,096 |
kW-mo/yr
|
$8.49 |
| Natural Gas | $696,716 | 265,718 |
MMBtu
|
$2.62 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $25,339 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 3.4111: Use closed cycle process to minimize waste water production | $13,500 | $25,100 | - | - | - |
$13,500
-
Tgal
|
|
| 02 | 2.4221: Install compressor air intakes in coolest locations | $5,701 | $4,500 |
$2,822
125,440
kWh
|
$2,879
-
kW-mo/yr
|
- | - | |
| 03 | 2.1213: Direct warmest air to combustion intake | $3,600 | $1,720 | - | - |
$3,600
-
MMBtu
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,164 | $1,652 |
$1,182
52,462
kWh
|
$982
-
kW-mo/yr
|
- | - | |
| 05 | 2.4133: Use most efficient type of electric motors | $374 | $684 |
$130
5,862
kWh
|
$244
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $25,339 | $33,656 |
$4,134
183,764
kWh
|
$4,105
-
kW-mo/yr
|
$3,600
-
MMBtu
|
$13,500
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs