| Assessment Year | 1995 |
|---|---|
| Principal Product | Hydraulic cylinders |
| NAICS |
n/a
|
| SIC | 3593: Fluid Power Cylinders and Actuators |
| Sales Range | $1 M to 5M |
| # of Employees | 90 |
| Plant Area |
79,000,000
ft2
|
| Annual Production | 4,500
pieces
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | Nebraska |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $66,214 | 1,092,614 |
kWh
|
$0.061 |
| Natural Gas | $21,504 | 5,778 |
MMBtu
|
$3.72 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $65,213 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,777 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,991 | $245 |
$10,991
181,419
kWh
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,009 | $50 |
$3,009
49,531
kWh
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,448 | $93 |
$1,448
24,033
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,481 | $4,837 |
$1,481
24,326
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $380 | $136 |
$380
6,155
kWh
|
- | |
| 06 | 2.7135: Install occupancy sensors | $124 | $231 |
$124
2,052
kWh
|
- | |
| 07 | 2.8123: Pay utility bills on time | $936 | - |
$936
-
kWh
|
- | |
| 08 | 2.4322: Use or replace with energy efficient substitutes | $2,841 | $12,000 |
$2,841
46,600
kWh
|
- | |
| 09 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $35,460 | $500 | - |
$35,460
-
lb
|
|
| 10 | 3.1163: Use plastic pallets instead of wood | $5,805 | $16,900 | - |
$5,805
-
lb
|
|
| 11 | 3.7115: Clean lines with "pigs" instead of solvents / solutions | $2,738 | $1,300 | - |
$2,738
-
lb
|
|
| TOTAL RECOMMENDED | $65,213 | $36,292 |
$21,210
334,116
kWh
|
$44,003
-
lb
|
||
| TOTAL IMPLEMENTED | $17,777 | $12,295 |
$17,777
277,550
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs