| Assessment Year | 1995 |
|---|---|
| Principal Product | packing equipment |
| NAICS |
n/a
|
| SIC | 3565: Packaging Machinery |
| Sales Range | $10 M to 50M |
| # of Employees | 175 |
| Plant Area |
200,000
ft2
|
| Annual Production | 300
pieces
|
| Production Hrs. Annual | 6,720
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $221,630 | 4,298,652 |
kWh
|
$0.052 |
| Natural Gas | $14,274 | 3,149 |
MMBtu
|
$4.53 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,071 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,239 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7124: Make a practice of turning off lights when not needed | $4,944 | $300 |
$4,944
95,838
kWh
|
- | - | |
| 02 | 2.7135: Install occupancy sensors | $1,738 | $2,999 |
$1,738
33,705
kWh
|
- | - | |
| 03 | 2.8123: Pay utility bills on time | $3,539 | - | - | - | $3,539 | |
| 04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $2,231 | $1,843 | - |
$2,231
-
MMBtu
|
- | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,094 | $20 |
$1,094
21,102
kWh
|
- | - | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $525 | $149 |
$525
10,258
kWh
|
- | - | |
| TOTAL RECOMMENDED | $14,071 | $5,311 |
$8,301
160,903
kWh
|
$2,231
-
MMBtu
|
$3,539 | ||
| TOTAL IMPLEMENTED | $11,239 | $2,292 |
$5,469
106,096
kWh
|
$2,231
-
MMBtu
|
$3,539 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs