| Assessment Year | 1994 |
|---|---|
| Principal Product | scales and weighing apparatus |
| NAICS |
n/a
|
| SIC | 3596: Scales and Balances, Except Laboratory |
| Sales Range | $10 M to 50M |
| # of Employees | 295 |
| Plant Area |
167,000
ft2
|
| Annual Production | 250,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Minnesota |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $227,794 | 3,687,280 |
kWh
|
$0.062 |
| Natural Gas | $27,132 | 7,381 |
MMBtu
|
$3.68 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $26,125 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,047 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,038 | $39,492 |
$18,038
291,911
kWh
|
- | |
| 02 | 2.7135: Install occupancy sensors | $1,520 | $2,683 |
$1,520
24,619
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $239 | $537 |
$239
3,810
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,195 | $136 |
$1,195
19,343
kWh
|
- | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $852 | $45 |
$852
13,775
kWh
|
- | |
| 06 | 2.8113: Purchase gas directly from a contract gas supplier | $4,281 | $4,200 | - | $4,281 | |
| TOTAL RECOMMENDED | $26,125 | $47,093 |
$21,844
353,458
kWh
|
$4,281 | ||
| TOTAL IMPLEMENTED | $2,047 | $181 |
$2,047
33,118
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs