Assessment Year | 1994 |
---|---|
Principal Product | grain drying equipment |
NAICS |
n/a
|
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
206,000
ft2
|
Annual Production | 16,000
pieces
|
Production Hrs. Annual | 2,170
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $64,138 | 1,369,871 |
kWh
|
$0.047 |
Natural Gas | $26,030 | 5,872 |
MMBtu
|
$4.43 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,382 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,269 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,332 | $1,285 |
$3,332
71,219
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $554 | $1,013 |
$554
11,723
kWh
|
- | |
03 | 2.7444: Close holes and openings in building such as broken windows | $1,738 | $995 |
$75
1,758
kWh
|
$1,663
-
MMBtu
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,369 | $1,000 |
$1,369
29,308
kWh
|
- | |
05 | 2.2437: Recover waste heat from equipment | $645 | $573 | - |
$645
-
MMBtu
|
|
06 | 2.3212: Optimize plant power factor | $744 | $3,210 |
$744
-
kWh
|
- | |
TOTAL RECOMMENDED | $8,382 | $8,076 |
$6,074
114,008
kWh
|
$2,308
-
MMBtu
|
||
TOTAL IMPLEMENTED | $6,269 | $3,866 |
$3,961
84,700
kWh
|
$2,308
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs