| Assessment Year | 1993 |
|---|---|
| Principal Product | pneumatic/electrical hand tools |
| NAICS |
n/a
|
| SIC | 3546: Power-Driven Handtools |
| Sales Range | $5 M to 10M |
| # of Employees | 200 |
| Plant Area |
229,750
ft2
|
| Annual Production | 2,000,000
pieces
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $140,482 | 2,987,984 |
kWh
|
$0.047 |
| Natural Gas | $33,000 | 9,234 |
MMBtu
|
$3.57 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,406 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,682 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,403 | $500 |
$10,403
221,278
kWh
|
- | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $691 | $200 |
$691
14,654
kWh
|
- | |
| 03 | 2.7243: Improve air circulation with destratification fans / other methods | $161 | $465 |
$161
3,517
kWh
|
- | |
| 04 | 2.7135: Install occupancy sensors | $3,872 | $2,343 |
$3,872
82,356
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,254 | $272 |
$1,254
26,671
kWh
|
- | |
| 06 | 2.2511: Insulate bare equipment | $25 | $43 | - |
$25
-
MMBtu
|
|
| TOTAL RECOMMENDED | $16,406 | $3,823 |
$16,381
348,476
kWh
|
$25
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $11,682 | $815 |
$11,657
247,949
kWh
|
$25
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs