| Assessment Year | 1991 |
|---|---|
| Principal Product | DAIRY PRODUCTS |
| NAICS |
n/a
|
| SIC | 2026: Fluid Milk |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
n/a
|
| Annual Production | 180,000,000
lb
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $253,353 | 5,817,995 |
kWh
|
$0.044 |
| Natural Gas | $68,792 | 24,431 |
MMBtu
|
$2.82 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,917 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $3,612 | $2,000 | - |
$3,612
-
MMBtu
|
- | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $2,516 | $250 |
$2,516
57,737
kWh
|
- | - | |
| 03 | 2.1213: Direct warmest air to combustion intake | $460 | $750 | - |
$460
-
MMBtu
|
- | |
| 04 | 2.1222: Install turbulators | $424 | $1,060 | - |
$424
-
MMBtu
|
- | |
| 05 | 2.4133: Use most efficient type of electric motors | $389 | $810 |
$389
9,086
kWh
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $516 | - |
$595
13,775
kWh
|
- | $(-79.0) | |
| TOTAL RECOMMENDED | $7,917 | $4,870 |
$3,500
80,598
kWh
|
$4,496
-
MMBtu
|
$(-79.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs