Assessment Year | 1991 |
---|---|
Principal Product | ALUMINUM CASTINGS |
NAICS |
n/a
|
SIC | 3365: Aluminum Foundries |
Sales Range | $5 M to 10M |
# of Employees | 110 |
Plant Area |
n/a
|
Annual Production | 1,000,000
lb
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $129,190 | 2,632,181 |
kWh
|
$0.049 |
Natural Gas | $136,641 | 48,635 |
MMBtu
|
$2.81 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,381 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,088 | $2,000 |
$7,088
144,490
kWh
|
- | |
02 | 2.2437: Recover waste heat from equipment | $2,408 | $686 | - |
$2,408
-
MMBtu
|
|
03 | 2.4133: Use most efficient type of electric motors | $427 | $1,095 |
$427
8,792
kWh
|
- | |
04 | 2.6232: Install set-back timers | $2,348 | - |
$2,348
48,066
kWh
|
- | |
05 | 2.6232: Install set-back timers | $1,110 | $1,200 |
$1,110
22,567
kWh
|
- | |
TOTAL RECOMMENDED | $13,381 | $4,981 |
$10,973
223,915
kWh
|
$2,408
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs