| Assessment Year | 2000 |
|---|---|
| Principal Product | Cut-up Poultry |
| NAICS |
n/a
|
| SIC | 2015: Poultry Slaughtering and Processing |
| Sales Range | $10 M to 50M |
| # of Employees | 130 |
| Plant Area |
75,000
ft2
|
| Annual Production | 53,000,000
lb
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $178,085 | 4,282,239 |
kWh
|
$0.042 |
| Electricity Demand | $112,670 | 11,798 |
kW-mo/yr
|
$9.55 |
| LPG | $3,803 | 5,112 |
MMBtu
|
$0.74 |
| Fuel Oil #2 | $149,243 | 42,547 |
MMBtu
|
$3.51 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $40,146 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,230 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4226: Use / purchase optimum sized compressor | $281 | $1,500 |
$281
6,741
kWh
|
- | - | - | |
| 02 | 2.2135: Repair and eliminate steam leaks | $7,450 | $400 | - |
$7,450
-
MMBtu
|
- | - | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $2,224 | $4,350 | - |
$2,224
-
MMBtu
|
- | - | |
| 04 | 3.7121: Improve handling practices | $3,900 | $4,000 | - | - | - | $3,900 | |
| 05 | 4.425: Eliminate/reduce redundant inspections | $3,900 | $1,260 | - | - | - | $3,900 | |
| 06 | 4.423: Move product using mechanical means | $645 | $225 | - | - | - | $645 | |
| 07 | 4.423: Move product using mechanical means | $780 | $650 | - | - | - | $780 | |
| 08 | 3.4151: Minimize water usage | $20,966 | $2,000 | - | - |
$20,966
-
Tgal
|
- | |
| TOTAL RECOMMENDED | $40,146 | $14,385 |
$281
6,741
kWh
|
$9,674
-
MMBtu
|
$20,966
-
Tgal
|
$9,225 | ||
| TOTAL IMPLEMENTED | $8,230 | $1,050 | - |
$7,450
-
MMBtu
|
- | $780 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs