| Assessment Year | 1999 |
|---|---|
| Principal Product | Precision Turned Components |
| NAICS |
n/a
|
| SIC | 3545: Cutting Tools, Machine Tool Accessories, and Machinists' Precision Measuring Devices |
| Sales Range | $5 M to 10M |
| # of Employees | 75 |
| Plant Area |
25,000
ft2
|
| Annual Production | 600,000
lb
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | Connecticut |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $44,284 | 662,368 |
kWh
|
$0.067 |
| Electricity Demand | $18,905 | 1,958 |
kW-mo/yr
|
$9.66 |
| Electricity Fees | $5,271 | - |
|
- |
| Natural Gas | $13,822 | 1,619 |
MMBtu
|
$8.54 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,888 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,456 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $736 | $2,782 |
$474
7,034
kWh
|
$262
-
kW-mo/yr
|
- | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $453 | $1,161 |
$453
6,741
kWh
|
- | - | - | |
| 03 | 2.7261: Install timers and/or thermostats | $6,391 | $1,880 |
$2,393
35,756
kWh
|
- |
$3,998
-
MMBtu
|
- | |
| 04 | 2.7424: Shade windows from summer sun | $3,456 | $6,000 |
$1,525
22,860
kWh
|
- |
$1,931
-
MMBtu
|
- | |
| 05 | 2.7243: Improve air circulation with destratification fans / other methods | $5,652 | $4,000 | - | - |
$5,652
-
MMBtu
|
- | |
| 06 | 4.611: Begin a practice of predictive / preventative maintenance | $1,200 | $120 | - | - | - | $1,200 | |
| 07 | 4.424: Improve space comfort conditioning | $1,000 | $3,282 | - | - | - | $1,000 | |
| TOTAL RECOMMENDED | $18,888 | $19,225 |
$4,845
72,391
kWh
|
$262
-
kW-mo/yr
|
$11,581
-
MMBtu
|
$2,200 | ||
| TOTAL IMPLEMENTED | $4,456 | $9,282 |
$1,525
22,860
kWh
|
- |
$1,931
-
MMBtu
|
$1,000 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs