| Assessment Year | 1999 |
|---|---|
| Principal Product | Custom millwork |
| NAICS |
n/a
|
| SIC | 2511: Wood Household Furniture, Except Upholstered |
| Sales Range | $1 M to 5M |
| # of Employees | 50 |
| Plant Area |
40,000
ft2
|
| Annual Production | 30
pieces
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $15,610 | 260,844 |
kWh
|
$0.060 |
| Electricity Demand | $20,194 | 1,436 |
kW-mo/yr
|
$14.06 |
| Electricity Fees | $10,849 | - |
|
- |
| Natural Gas | $30,622 | 4,265 |
MMBtu
|
$7.18 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,365 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,344 | $27,758 |
$3,551
59,203
kWh
|
$4,793
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.2136: Install / repair insulation on steam lines | $602 | $315 | - | - | $602 | - | - | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $1,381 | $1,295 | - | - | $1,381 | - | - | |
| 04 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $4,698 | $18,360 | - | - | $4,698 | - | - | |
| 05 | 2.7442: Keep doors and windows shut when not on use | $460 | $300 | - | - | $460 | - | - | |
| 06 | 4.424: Improve space comfort conditioning | $2,000 | $200 | - | - | - | - | $2,000 | |
| 07 | 3.5313: Increase amount of waste recovered for resale | $2,880 | $3,500 | - | - | - |
$2,880
-
lb
|
- | |
| TOTAL RECOMMENDED | $20,365 | $51,728 |
$3,551
59,203
kWh
|
$4,793
-
kW-mo/yr
|
$7,141 |
$2,880
-
lb
|
$2,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs