Assessment Year | 1998 |
---|---|
Principal Product | Printings |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
60,000
ft2
|
Annual Production | 171,864,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $153,723 | 1,829,133 |
kWh
|
$0.084 |
Electricity Demand | $56,273 | 8,142 |
kW-mo/yr
|
$6.91 |
Electricity Fees | $12,812 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $38,661 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,905 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $572 | $1,525 |
$510
5,862
kWh
|
$62
-
kW-mo/yr
|
- | - | - | |
02 | 2.7123: Keep lamps and reflectors clean | $1,669 | - |
$1,669
19,930
kWh
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $1,692 | $946 |
$1,692
2,931
kWh
|
- | - | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $755 | $500 |
$651
7,620
kWh
|
$104
-
kW-mo/yr
|
- | - | - | |
05 | 2.7224: Reduce space conditioning during non-working hours | $1,835 | - |
$1,835
21,688
kWh
|
- | - | - | - | |
06 | 3.7311: Maintain machines to reduce leaks | $360 | $100 | - | - | - | - | $360 | |
07 | 3.7141: Improve cleaning efficiency by maintaining cleaning system | $5,850 | $500 | - | - | - | $5,850 | - | |
08 | 4.211: Consider use / purchase of bulk materials where possible | $4,469 | $200 | - | - | - | - | $4,469 | |
09 | 2.8114: Change rate schedules or other changes in utility service | $21,459 | $27,500 | - | - | $21,459 | - | - | |
TOTAL RECOMMENDED | $38,661 | $31,271 |
$6,357
58,031
kWh
|
$166
-
kW-mo/yr
|
$21,459 | $5,850 | $4,829 | ||
TOTAL IMPLEMENTED | $8,905 | $1,825 |
$4,014
47,480
kWh
|
$62
-
kW-mo/yr
|
- | - | $4,829 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs