Assessment Year | 1996 |
---|---|
Principal Product | Metal doors and frames |
NAICS |
n/a
|
SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
Sales Range | $10 M to 50M |
# of Employees | 185 |
Plant Area |
165,000
ft2
|
Annual Production | 300,000
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $163,087 | 1,859,613 |
kWh
|
$0.088 |
Electricity Demand | $73,638 | 7,949 |
kW-mo/yr
|
$9.26 |
Electricity Fees | $(-20,768.0) | - |
|
- |
Natural Gas | $76,609 | 18,913 |
MMBtu
|
$4.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,481 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,981 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,476 | $48,874 |
$10,254
116,940
kWh
|
$5,222
-
kW-mo/yr
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $562 | $1,215 |
$562
6,448
kWh
|
- | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,943 | $800 |
$1,291
14,654
kWh
|
$652
-
kW-mo/yr
|
- | |
04 | 3.2124: Convert to air assisted / airless paint guns | $1,500 | $2,000 | - | - |
$1,500
-
gal
|
|
TOTAL RECOMMENDED | $19,481 | $52,889 |
$12,107
138,042
kWh
|
$5,874
-
kW-mo/yr
|
$1,500
-
gal
|
||
TOTAL IMPLEMENTED | $17,981 | $50,889 |
$12,107
138,042
kWh
|
$5,874
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs