Assessment Year | 1996 |
---|---|
Principal Product | Automotive Accessories |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $50 M to 100M |
# of Employees | 160 |
Plant Area |
90,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $116,797 | 412,954 |
kWh
|
$0.28 |
Electricity Fees | $4,697 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,282 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,852 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,672 | $2,866 |
$5,672
19,343
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,280 | $6,484 |
$6,280
21,395
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $2,975 | $3,110 |
$2,975
10,258
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,573 | $400 |
$1,573
5,275
kWh
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,352 | $180 |
$3,352
11,430
kWh
|
- | |
06 | 3.6192: Use a less expensive method of waste removal | $5,430 | - | - |
$5,430
-
lb
|
|
TOTAL RECOMMENDED | $25,282 | $13,040 |
$19,852
67,701
kWh
|
$5,430
-
lb
|
||
TOTAL IMPLEMENTED | $19,852 | $13,040 |
$19,852
67,701
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs