| Assessment Year | 1995 |
|---|---|
| Principal Product | Gears |
| NAICS |
n/a
|
| SIC | 3566: Speed Changers, Industrial High-Speed Drives, and Gears |
| Sales Range | $10 M to 50M |
| # of Employees | 300 |
| Plant Area |
55,000
ft2
|
| Annual Production | 84,000
lb
|
| Production Hrs. Annual | 4,264
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $179,396 | 1,216,589 |
kWh
|
$0.15 |
| Fuel Oil #2 | $18,294 | 2,989 |
MMBtu
|
$6.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,834 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,845 | $6,502 |
$12,845
87,339
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,841 | $4,231 |
$3,841
26,084
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $342 | $450 |
$342
2,345
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $964 | $400 |
$964
6,448
kWh
|
- | |
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $842 | $1,500 |
$1,024
7,034
kWh
|
$(-182.0)
-
MMBtu
|
|
| TOTAL RECOMMENDED | $18,834 | $13,083 |
$19,016
129,250
kWh
|
$(-182.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs