Assessment Year | 1995 |
---|---|
Principal Product | Acrylic Sheets |
NAICS |
n/a
|
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
70,000
ft2
|
Annual Production | 12,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Connecticut |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $374,169 | 5,210,434 |
kWh
|
$0.072 |
Natural Gas | $709,420 | 142,221 |
MMBtu
|
$4.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $39,523 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,993 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,552 | $6,151 |
$4,552
63,306
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $1,441 | $1,363 |
$1,441
19,930
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $2,318 | $1,000 |
$2,318
32,239
kWh
|
- | |
04 | 2.1232: Keep boiler tubes clean | $31,212 | $2,500 | - |
$31,212
-
MMBtu
|
|
TOTAL RECOMMENDED | $39,523 | $11,014 |
$8,311
115,475
kWh
|
$31,212
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,993 | $7,514 |
$5,993
83,236
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs