| Assessment Year | 1995 |
|---|---|
| Principal Product | Acrylic Sheets |
| NAICS |
n/a
|
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
70,000
ft2
|
| Annual Production | 12,000,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Connecticut |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $374,169 | 5,210,434 |
kWh
|
$0.072 |
| Natural Gas | $709,420 | 142,221 |
MMBtu
|
$4.99 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $39,523 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,993 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,552 | $6,151 |
$4,552
63,306
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $1,441 | $1,363 |
$1,441
19,930
kWh
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $2,318 | $1,000 |
$2,318
32,239
kWh
|
- | |
| 04 | 2.1232: Keep boiler tubes clean | $31,212 | $2,500 | - |
$31,212
-
MMBtu
|
|
| TOTAL RECOMMENDED | $39,523 | $11,014 |
$8,311
115,475
kWh
|
$31,212
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $5,993 | $7,514 |
$5,993
83,236
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs