Assessment Year | 1995 |
---|---|
Principal Product | Point of Purchase Displays |
NAICS |
n/a
|
SIC | 2542: Office and Store Fixtures, Partitions, Shelving, and Lockers, Except Wood |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
110,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,300
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $111,720 | 779,015 |
kWh
|
$0.14 |
Natural Gas | $37,617 | 6,029 |
MMBtu
|
$6.24 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,251 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,557 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,358 | $1,285 |
$1,358
9,379
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $595 | $1,174 |
$595
4,103
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $273 | $688 |
$273
2,052
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $1,855 | $1,000 |
$1,855
12,896
kWh
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $254 | $580 |
$254
1,758
kWh
|
|
06 | 2.7124: Make a practice of turning off lights when not needed | $1,421 | $200 |
$1,421
9,965
kWh
|
|
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,495 | $360 |
$3,495
24,326
kWh
|
|
TOTAL RECOMMENDED | $9,251 | $5,287 |
$9,251
64,479
kWh
|
||
TOTAL IMPLEMENTED | $7,557 | $4,399 |
$7,557
52,462
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs