Assessment Year | 1994 |
---|---|
Principal Product | Sheet Metal Products |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $5 M to 10M |
# of Employees | 60 |
Plant Area |
50,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,588
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $48,263 | 381,008 |
kWh
|
$0.13 |
Natural Gas | $22,427 | 4,909 |
MMBtu
|
$4.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,179 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,147 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,879 | $3,712 |
$3,879
30,481
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $700 | $1,600 |
$700
5,569
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $304 | $710 |
$304
2,345
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $810 | $500 |
$810
6,448
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $918 | $740 |
$918
7,327
kWh
|
- | |
06 | 2.7124: Make a practice of turning off lights when not needed | $3,568 | $600 |
$1,428
11,137
kWh
|
$2,140
-
MMBtu
|
|
TOTAL RECOMMENDED | $10,179 | $7,862 |
$8,039
63,307
kWh
|
$2,140
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,147 | $5,912 |
$6,007
47,187
kWh
|
$2,140
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs