Assessment Year | 1994 |
---|---|
Principal Product | Custom Envelopes |
NAICS |
n/a
|
SIC | 2677: Envelopes |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
140,000
ft2
|
Annual Production | 28,600,000
lb
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $557,751 | 6,703,986 |
kWh
|
$0.083 |
Natural Gas | $41,469 | 8,111 |
MMBtu
|
$5.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,222 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,343 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,343 | $7,966 |
$8,343
100,528
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,343 | $12,043 |
$5,343
64,478
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $1,480 | $1,890 |
$1,480
17,878
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $5,586 | $2,100 |
$5,586
66,237
kWh
|
|
05 | 2.2691: Shut off cooling if cold outside air will cool process | $7,470 | $10,000 |
$7,470
89,977
kWh
|
|
TOTAL RECOMMENDED | $28,222 | $33,999 |
$28,222
339,098
kWh
|
||
TOTAL IMPLEMENTED | $5,343 | $12,043 |
$5,343
64,478
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs