Assessment Year | 1994 |
---|---|
Principal Product | Corrugated boxes |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $5 M to 10M |
# of Employees | 37 |
Plant Area |
70,000
ft2
|
Annual Production | 22,340
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $58,624 | 637,456 |
kWh
|
$0.092 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,963 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,509 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,254 | $1,557 |
$2,254
24,619
kWh
|
|
02 | 2.7144: Install spectral reflectors / delamp | $924 | $1,088 |
$924
8,792
kWh
|
|
03 | 2.7111: Reduce illumination to minimum necessary levels | $279 | - |
$279
3,810
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $362 | $360 |
$362
3,517
kWh
|
|
05 | 2.4133: Use most efficient type of electric motors | $813 | $1,902 |
$813
8,792
kWh
|
|
06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,331 | - |
$1,331
-
kWh
|
|
TOTAL RECOMMENDED | $5,963 | $4,907 |
$5,963
49,530
kWh
|
||
TOTAL IMPLEMENTED | $4,509 | $2,645 |
$4,509
33,411
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs