| Assessment Year | 1993 |
|---|---|
| Principal Product | Plastic Molded Products |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 25 |
| Plant Area |
42,000
ft2
|
| Annual Production | 500
ton
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $41,108 | 340,563 |
kWh
|
$0.12 |
| Natural Gas | $50,848 | 8,978 |
MMBtu
|
$5.66 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,320 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,603 | $1,940 |
$3,603
29,894
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,481 | $1,923 |
$1,481
12,309
kWh
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $199 | $204 |
$199
1,758
kWh
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $870 | $1,000 |
$870
7,327
kWh
|
|
| 05 | 2.2511: Insulate bare equipment | $167 | $96 |
$167
8,792
kWh
|
|
| TOTAL RECOMMENDED | $6,320 | $5,163 |
$6,320
60,080
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs