Assessment Year | 1993 |
---|---|
Principal Product | Heat Shrinkable PVC Labels |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
100,000
ft2
|
Annual Production | 2,400
ton
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $250,701 | 2,245,604 |
kWh
|
$0.11 |
Natural Gas | $58,052 | 12,566 |
MMBtu
|
$4.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,813 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,061 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,061 | $1,614 |
$3,061
27,257
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,391 | $2,202 |
$1,391
12,603
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $1,201 | $2,038 |
$1,201
10,844
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $1,160 | $1,000 |
$1,160
10,258
kWh
|
|
TOTAL RECOMMENDED | $6,813 | $6,854 |
$6,813
60,962
kWh
|
||
TOTAL IMPLEMENTED | $3,061 | $1,614 |
$3,061
27,257
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs