Assessment Year | 1993 |
---|---|
Principal Product | Plating Processes |
NAICS |
n/a
|
SIC | 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
88,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,860
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $125,144 | 2,250,000 |
kWh
|
$0.056 |
Natural Gas | $73,007 | 14,871 |
MMBtu
|
$4.91 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,246 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,438 | $2,315 |
$1,438
25,791
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $240 | $1,095 |
$240
4,396
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $249 | $617 |
$249
4,396
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $145 | $300 |
$145
2,638
kWh
|
- | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,607 | $2,200 | - |
$3,607
-
MMBtu
|
|
06 | 2.1211: Move boiler to more efficient location | $567 | $274 | - |
$567
-
MMBtu
|
|
TOTAL RECOMMENDED | $6,246 | $6,801 |
$2,072
37,221
kWh
|
$4,174
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs