| Assessment Year | 1993 |
|---|---|
| Principal Product | Plastic Bags |
| NAICS |
n/a
|
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $5 M to 10M |
| # of Employees | 35 |
| Plant Area |
75,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $234,376 | 2,285,170 |
kWh
|
$0.10 |
| Natural Gas | $31,715 | 5,909 |
MMBtu
|
$5.37 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,178 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,081 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,713 | $77 |
$2,713
26,377
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,759 | $143 |
$1,759
17,292
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $1,669 | $522 |
$1,669
16,120
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $779 | $1,000 |
$779
7,620
kWh
|
- | |
| 05 | 2.7243: Improve air circulation with destratification fans / other methods | $8,428 | $4,000 |
$(-331.0)
(-3,224)
kWh
|
$8,759
-
MMBtu
|
|
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,830 | $180 |
$1,830
17,878
kWh
|
- | |
| TOTAL RECOMMENDED | $17,178 | $5,922 |
$8,419
82,063
kWh
|
$8,759
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $7,081 | $1,400 |
$7,081
69,167
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs