| Assessment Year | 1993 |
|---|---|
| Principal Product | Metal Tubing |
| NAICS |
n/a
|
| SIC | 3443: Fabricated Plate Work (Boiler Shops) |
| Sales Range | $10 M to 50M |
| # of Employees | 185 |
| Plant Area |
350,000
ft2
|
| Annual Production | 156,000,000
thousand feet
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $537,543 | 7,486,518 |
kWh
|
$0.072 |
| Natural Gas | $272,182 | 139,279 |
MMBtu
|
$1.95 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $19,505 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $918 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,752 | $8,530 |
$8,752
121,630
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,699 | $13,825 |
$4,699
65,358
kWh
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $918 | $1,967 |
$918
12,896
kWh
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $5,136 | $1,000 |
$5,136
71,512
kWh
|
|
| TOTAL RECOMMENDED | $19,505 | $25,322 |
$19,505
271,396
kWh
|
||
| TOTAL IMPLEMENTED | $918 | $1,967 |
$918
12,896
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs