| Assessment Year | 1992 |
|---|---|
| Principal Product | STEEL DOORS |
| NAICS |
n/a
|
| SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
| Sales Range | $1 M to 5M |
| # of Employees | 110 |
| Plant Area |
n/a
|
| Annual Production | 37,500
pieces
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $69,348 | 466,589 |
kWh
|
$0.15 |
| Natural Gas | $38,625 | 6,724 |
MMBtu
|
$5.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,962 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,399 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,111 | $159 |
$1,223
8,206
kWh
|
$(-112.0) | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $533 | $(-529.0) |
$533
3,517
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $30 | $22 |
$30
293
kWh
|
- | |
| 04 | 2.4322: Use or replace with energy efficient substitutes | $507 | $2,000 |
$507
25,791
kWh
|
- | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $218 | $250 |
$218
1,465
kWh
|
- | |
| 06 | 2.8112: Combine utility meters | $7,725 | $2,000 |
$7,725
-
kWh
|
- | |
| 07 | 2.8121: Apply for tax-free status for energy purchases | $1,838 | $200 |
$1,838
-
kWh
|
- | |
| TOTAL RECOMMENDED | $11,962 | $4,102 |
$12,074
39,272
kWh
|
$(-112.0) | ||
| TOTAL IMPLEMENTED | $9,399 | $1,652 |
$9,511
12,016
kWh
|
$(-112.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs