ITAC Assessment: HO0028
ITAC logo
ITAC Assessment: HO0028
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1992
Principal Product PLASTIC FILM
NAICS
n/a
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 42
Plant Area
n/a
Annual Production 5,000
ton
Production Hrs. Annual 4,375
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $113,879 863,716
kWh
Natural Gas $19,668 3,223
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $6,226 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Fuel Oil #2 Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $3,202 $2,483 $3,390
25,791
kWh
- $(-188.0)
02 2.7142: Utilize higher efficiency lamps and/or ballasts $1,584 $562 $1,584
12,016
kWh
- -
03 2.4133: Use most efficient type of electric motors $387 $140 $387
2,931
kWh
- -
04 2.2136: Install / repair insulation on steam lines $79 $132 - $79
-
MMBtu
-
05 2.4221: Install compressor air intakes in coolest locations $974 $1,000 $974
7,327
kWh
- -
TOTAL RECOMMENDED $6,226 $4,317 $6,335
48,065
kWh
$79
-
MMBtu
$(-188.0)
TOTAL IMPLEMENTED - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs