| Assessment Year | 1992 |
|---|---|
| Principal Product | PLASTIC FILM |
| NAICS |
n/a
|
| SIC | 2759: Commercial Printing, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 42 |
| Plant Area |
n/a
|
| Annual Production | 5,000
ton
|
| Production Hrs. Annual | 4,375
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $113,879 | 863,716 |
kWh
|
$0.13 |
| Natural Gas | $19,668 | 3,223 |
MMBtu
|
$6.10 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,226 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,202 | $2,483 |
$3,390
25,791
kWh
|
- | $(-188.0) | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,584 | $562 |
$1,584
12,016
kWh
|
- | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $387 | $140 |
$387
2,931
kWh
|
- | - | |
| 04 | 2.2136: Install / repair insulation on steam lines | $79 | $132 | - |
$79
-
MMBtu
|
- | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $974 | $1,000 |
$974
7,327
kWh
|
- | - | |
| TOTAL RECOMMENDED | $6,226 | $4,317 |
$6,335
48,065
kWh
|
$79
-
MMBtu
|
$(-188.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs