Assessment Year 2026
Principal Product Demountable Interior Walls
NAICS 332321: Metal Window and Door Manufacturing
SIC 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing
Sales Range $50
M
to 100
M
# of Employees 198
Plant Area 82,000
ft2
Annual Production 499,549
pieces
Production Hrs. Annual 6,300
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $191,021 1,369,120
kWh
Natural Gas $24,677 3,580
MMBtu
Other Gas $1,728 1
MMBtu
TOTAL YEARLY COSTS $217,426
RECOMMENDED SAVINGS* $130,803 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Other Gas Savings Personnel Changes Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $34,896 $1,850 $37,796
269,971
kWh
- - $(-2,900.0)
02 2.4231: Reduce the pressure of compressed air to the minimum required $3,071 $400 $3,071
21,939
kWh
- - -
03 2.8121: Apply for tax-free status for energy purchases $1,463 $200 - - $1,463
-
MMBtu
-
04 2.4239: Eliminate or reduce compressed air usage $10,214 $2,000 $10,214
72,965
kWh
- - -
05 2.2511: Insulate bare equipment $2,548 $640 - $2,548
-
MMBtu
- -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $2,778 $2,389 $2,778
19,845
kWh
- - -
07 2.7447: Install vinyl strip / high speed / air curtain doors $7,162 $8,061 $3,242
23,154
kWh
$3,920
-
MMBtu
- -
08 2.6212: Turn off equipment during breaks, reduce operating time $515 $680 $515
3,679
kWh
- - -
09 2.4324: Replace hydraulic / pneumatic equipment with electric equipment $3,355 $8,200 $3,355
23,968
kWh
- - -
10 2.9114: Use solar heat to make electricty $64,801 $290,462 $64,801
464,455
kWh
- - -
TOTAL RECOMMENDED $130,803 $314,882 $125,772
899,976
kWh
$6,468
-
MMBtu
$1,463
-
MMBtu
$(-2,900.0)
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Other Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs