Assessment Year | 2025 |
---|---|
Principal Product | Commercial Refrigeration Systems |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $50 M to 100M |
# of Employees | 174 |
Plant Area |
123,062
ft2
|
Annual Production | 230
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $233,640 | 1,375,075 |
kWh
|
$0.17 |
Electricity Fees | $329 | - |
|
- |
Natural Gas | $15,801 | 1,566 |
MMBtu
|
$10.09 |
Other Gas | $1,247 | 1 |
MMBtu
|
$1,247.45 |
TOTAL YEARLY COSTS | $251,017 | |||
RECOMMENDED SAVINGS* | $62,231 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $1,089 | $200 | - |
$1,089
-
MMBtu
|
- | |
02 | 2.6211: Conserve energy by efficient use of vending machines | $385 | $90 |
$385
2,268
kWh
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $1,796 | $500 |
$1,796
10,562
kWh
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $432 | $200 |
$432
2,540
kWh
|
- | - | |
05 | 2.6231: Utilize controls to operate equipment only when needed | $469 | $313 |
$469
2,757
kWh
|
- | - | |
06 | 2.6212: Turn off equipment during breaks, reduce operating time | $746 | $567 |
$746
4,389
kWh
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,769 | $1,850 |
$3,469
20,407
kWh
|
- | $(-1,700.0) | |
08 | 2.9114: Use solar heat to make electricty | $55,545 | $269,534 |
$55,545
326,906
kWh
|
- | - | |
TOTAL RECOMMENDED | $62,231 | $273,254 |
$62,842
369,829
kWh
|
$1,089
-
MMBtu
|
$(-1,700.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Other Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs