Assessment Year | 2022 |
---|---|
Principal Product | Cans and Bottles of Soft Drinks |
NAICS | 312111: Soft Drink Manufacturing |
SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
Sales Range | $50 M to 100M |
# of Employees | 250 |
Plant Area |
400,000
ft2
|
Annual Production | 25,767,985
units
|
Production Hrs. Annual | 6,900
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,581,034 | 14,442,494 |
kWh
|
$0.11 |
Natural Gas | $211,457 | 48,630 |
MMBtu
|
$4.35 |
TOTAL YEARLY COSTS | $1,792,491 | |||
RECOMMENDED SAVINGS* | $631,294 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $110,715 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $93,972 | $800 | - | $93,972 | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $16,743 | $1,850 |
$19,643
180,210
kWh
|
- | $(-2,900.0) | |
03 | 2.6231: Utilize controls to operate equipment only when needed | $151,488 | $44,117 |
$151,488
1,389,798
kWh
|
- | - | |
04 | 2.6211: Conserve energy by efficient use of vending machines | $326 | $200 |
$326
2,994
kWh
|
- | - | |
05 | 2.9114: Use solar heat to make electricty | $368,765 | $3,913,242 |
$368,765
3,368,613
kWh
|
- | - | |
TOTAL RECOMMENDED | $631,294 | $3,960,209 |
$540,222
4,941,615
kWh
|
$93,972 | $(-2,900.0) | ||
TOTAL IMPLEMENTED | $110,715 | $2,650 |
$19,643
180,210
kWh
|
$93,972 | $(-2,900.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs