Assessment Year | 1996 |
---|---|
Principal Product | Insulated electric heating/freezing protection for pipes, va |
NAICS |
n/a
|
SIC | 3357: Drawing and Insulating of Nonferrous Wire |
Sales Range | $50 M to 100M |
# of Employees | 290 |
Plant Area |
94,000
ft2
|
Annual Production | 6,000
thousand feet
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $95,676 | 2,597,011 |
kWh
|
$0.037 |
Electricity Demand | $75,626 | 8,593 |
kW-mo/yr
|
$8.80 |
Electricity Fees | $1,003 | - |
|
- |
Natural Gas | $3,215 | 826 |
MMBtu
|
$3.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,708 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,068 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $7,585 | $10,350 |
$7,585
216,882
kWh
|
- | - | - | - | |
02 | 2.8114: Change rate schedules or other changes in utility service | $1,930 | - | - | - | $1,930 | - | - | |
03 | 2.7145: Install skylights | $1,435 | $2,870 |
$1,435
41,032
kWh
|
- | - | - | - | |
04 | 2.8112: Combine utility meters | $1,390 | $500 | - | - | $1,390 | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $720 | $1,570 |
$130
3,810
kWh
|
$50
-
kW-mo/yr
|
- | - | $540 | |
06 | 2.8123: Pay utility bills on time | $508 | - | - | - | $508 | - | - | |
07 | 2.7111: Reduce illumination to minimum necessary levels | $370 | $120 |
$160
4,982
kWh
|
$210
-
kW-mo/yr
|
- | - | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $370 | $300 |
$370
10,551
kWh
|
- | - | - | - | |
09 | 2.7124: Make a practice of turning off lights when not needed | $100 | - |
$100
3,517
kWh
|
- | - | - | - | |
10 | 3.6192: Use a less expensive method of waste removal | $860 | - | - | - | - |
$860
-
lb
|
- | |
11 | 3.5217: Reuse / recycle/ sell paper products | $440 | - | - | - | - |
$440
-
lb
|
- | |
TOTAL RECOMMENDED | $15,708 | $15,710 |
$9,780
280,774
kWh
|
$260
-
kW-mo/yr
|
$3,828 |
$1,300
-
lb
|
$540 | ||
TOTAL IMPLEMENTED | $4,068 | $1,870 |
$600
17,878
kWh
|
$50
-
kW-mo/yr
|
$2,438 |
$440
-
lb
|
$540 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs