Assessment Year 2021
Principal Product Gear/Progressing Cavity Pumps & Flow Dividers
NAICS 333911: Pump and Pumping Equipment Manufacturing
SIC 3561: Pumps and Pumping Equipment
Sales Range $10
M
to 50
M
# of Employees 168
Plant Area 150,000
ft2
Annual Production 29,520
units
Production Hrs. Annual 4,810
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $657,427 6,242,952
kWh
Natural Gas $106,736 12,227
MMBtu
TOTAL YEARLY COSTS $764,163
RECOMMENDED SAVINGS* $174,058 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $93,855

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
01 2.6218: Turn off equipment when not in use $17,635 $350 $20,235
192,167
kWh
- $(-2,600.0)
02 2.7229: Air condition only space necessary $4,101 $200 $918
8,715
kWh
$3,183
-
MMBtu
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $15,872 $1,050 $18,772
178,269
kWh
- $(-2,900.0)
04 2.2625: Chill water to the highest temperature possible $1,152 $250 $1,152
10,942
kWh
- -
05 2.7261: Install timers and/or thermostats $3,211 $1,067 $2,851
27,071
kWh
$360
-
MMBtu
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $53,036 $38,422 $53,036
503,665
kWh
- -
07 2.2511: Insulate bare equipment $1,020 $813 - $1,020
-
MMBtu
-
08 2.9114: Use solar heat to make electricty $78,031 $737,508 $78,031
739,059
kWh
- -
TOTAL RECOMMENDED $174,058 $779,660 $174,994
1,659,888
kWh
$4,564
-
MMBtu
$(-5,500.0)
TOTAL IMPLEMENTED $93,855 $41,089 $95,811
909,887
kWh
$3,544
-
MMBtu
$(-5,500.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs