| Assessment Year | 2021 |
|---|---|
| Principal Product | Lighting |
| NAICS | 335129: Other Lighting Equipment Manufacturing |
| SIC | 3648: Lighting Equipment, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
750,000
ft2
|
| Annual Production | 1,700,000
units
|
| Production Hrs. Annual | 7,500
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $756,812 | 8,485,134 |
kWh
|
$0.089 |
| Natural Gas | $77,183 | 14,836 |
MMBtu
|
$5.20 |
| TOTAL YEARLY COSTS | $833,995 | |||
| RECOMMENDED SAVINGS* | $91,290 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $74,499 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4226: Use / purchase optimum sized compressor | $11,232 | $200 |
$11,232
125,927
kWh
|
- | - | |
| 02 | 2.8121: Apply for tax-free status for energy purchases | $53,832 | $2,000 | - | $53,832 | - | |
| 03 | 2.6211: Conserve energy by efficient use of vending machines | $304 | $13 |
$304
3,411
kWh
|
- | - | |
| 04 | 2.6218: Turn off equipment when not in use | $4,488 | $300 |
$4,488
50,316
kWh
|
- | - | |
| 05 | 2.3132: Recharge batteries on during off-peak demand periods | $5,728 | $400 | - | $5,728 | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,379 | $1,850 |
$6,279
70,398
kWh
|
- | $(-2,900.0) | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,264 | $1,734 |
$1,264
14,198
kWh
|
- | - | |
| 08 | 2.6218: Turn off equipment when not in use | $10,763 | $18,887 |
$10,763
120,931
kWh
|
- | - | |
| 09 | 2.3212: Optimize plant power factor | $300 | $1,565 | - | $300 | - | |
| TOTAL RECOMMENDED | $91,290 | $26,948 |
$34,330
385,181
kWh
|
$59,861 | $(-2,900.0) | ||
| TOTAL IMPLEMENTED | $74,499 | $6,096 |
$23,567
264,250
kWh
|
$53,832 | $(-2,900.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs