| Assessment Year | 2019 |
|---|---|
| Principal Product | Aircraft Propeller Systems |
| NAICS | 336411: Aircraft Manufacturing |
| SIC | 3724: Aircraft Engines and Engine Parts |
| Sales Range | $10 M to 50M |
| # of Employees | 60 |
| Plant Area |
100,000
ft2
|
| Annual Production | 3,000
units
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $310,838 | 3,545,297 |
kWh
|
$0.088 |
| Natural Gas | $30,983 | 3,017 |
MMBtu
|
$10.27 |
| TOTAL YEARLY COSTS | $341,821 | |||
| RECOMMENDED SAVINGS* | $41,040 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $34,572 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7224: Reduce space conditioning during non-working hours | $17,607 | $950 |
$17,607
200,082
kWh
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,605 | $1,741 |
$1,605
18,241
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,360 | $33,097 |
$15,360
174,545
kWh
|
|
| 04 | 2.7311: Ventilation system to shut off when room is not in use | $3,786 | $9,100 |
$3,786
43,025
kWh
|
|
| 05 | 2.7313: Recycle air for heating, ventilation and air conditioning | $2,682 | $7,500 |
$2,682
30,472
kWh
|
|
| TOTAL RECOMMENDED | $41,040 | $52,387 |
$41,040
466,366
kWh
|
||
| TOTAL IMPLEMENTED | $34,572 | $35,787 |
$34,572
392,868
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs